Print
Back to: Category 6 LAN cables
Category 6 LAN cables

F/UTP Cat.6 4Pr Outdoor

Temple_copy__1581525118_663
Rating: Not Rated Yet
Product Code:
Ai intrebari sau ai nevoie de asistenta pentru finalizarea comenzii ?
Trimite mail la : adresa@e.mail
Disponibilitate: Stoc epuizat

Application

PBX, V.11, X.21, ISDN, Ethernet (10Base-T), ATM-25/52/155 Mbit/s, 100VG-AnyLAN, Fast Ethernet (100BASE-TX), Token Ring 16/100 Mbit/s, Firewire 100 Mbit/s, PoE (IEEE 802.3af), PoE+ (IEEE 802.3at), PoE++ (IEEE 802.3bt), HDBaseT, 1000BASE-T, 2.5GBASE-T, 5GBASE-T, 10GBASE-T (до 55 метров)

Typical design

 
Cable structure

1. Conducting conductor (TPA): annealed copper wire
2. Insulation: solid, PE
3. Pair: two insulated conductors twisted together with agreed steps and with the following color identification:
- pair 1: white-blue / blue
- pair 2: white-orange / orange
- pair 3: white-green / green
- pair 4: white-brown / brown
4. Pair separator (cordel): PE
5. Belt insulation: PET-E film, overlapping
6. Core screen: aluminum-polymer tape (metal inside)
7. Drain conductor: tinned copper wire with a diameter of 0.4 mm (under the screen)
8. Obolo chka: light stabilized black PE

Standards / TU

Cable requirement: DSTU IEC 61156-5, DSTU EN 50288-5-1, TU U 27.3-05758730-097: 2018
Cable requirement: DSTU ISO / IEC 11801, DSTU EN 50173-1

Main technical and operational characteristics

Temperature range:
- during installation: -10 ° C ... + 60 ° C
- during operation: -50 ° C ... + 60 ° C
Bending radius: ≥ 10 cable diameters
Tensile force: ≤ 85 N

Electrical characteristics at 20 0 С

Parameter Ed. ed. Value
Working capacity, no more nF / km 56
Electrical resistance tfzh to direct current: Om / km  
- with a diameter of 0.54 mm, no more   83
- with a diameter of TPG 0.57 mm, not more than   88
Ohmic asymmetry lived in pairs, no more % 2
Electrical insulation resistance, not less GOm / km 5
Nominal signal propagation speed % 68
Wave impedance module Ohm  
- in the frequency range from 1 to 100 MHz   100 +/- 15
- in the frequency range from 101 to 250 MHz   100 +/- 22
DC test voltage between conductors, conductors and shield for 2 seconds kV 2.5

Signal transmission characteristics at 20 0 C

Frequency, MHz 1 4 10 16 20 31.25 62.5 100 250
Own attenuation, dB / 100 m, no more 2.1 3.8 6 7.6 8.5 10.7 15.5 19.9 33
NEXT, dB, not less 75.3 66.3 60.3 57.2 55.8 52.9 48.4 45.3 39.3
PS NEXT, dB, not less 72.3 63.3 57.3 54.2 52.8 49.9 45.4 42.3 36.3
ELFEXT, dB, not less 68 56 48 43.9 42 38.1 32.1 28 20
PS ELFEXT, dB, not less 65 53 45 40.9 39 35.1 29.1 25 17
Return Loss, dB, not less 20 2. 3 25 25 25 23.6 21.5 20.1 17.3

Order Information

Code Name Shell Diameter of TPG, mm Conductor diameter mm Diameter / cable size, mm Packaging Estimated weight, kg / km
7934017 KPPE-VP (250) 4 * 2 * 0.57 (F / UTP-cat.6) ON 0.57 1.11 7.1 plywood coil 305/500/1000 m 45.9
7934018 KPPE-VP (250) 4 * 2 * 0.54 (F / UTP-cat.6) ON 0.54 1.03 6.9 plywood coil 305/500/1000 m 42.7