PBX, V.11, X.21, ISDN, Ethernet (10Base-T), ATM-25/52/155 Mbit/s, 100VG-AnyLAN, Fast Ethernet (100BASE-TX), Token Ring 16/100 Mbit/s, Firewire 100 Mbit/s, PoE (IEEE 802.3af), PoE+ (IEEE 802.3at), PoE++ (IEEE 802.3bt), HDBaseT, 1000BASE-T, 2.5GBASE-T, 5GBASE-T, 10GBASE-T (до 55 метров)
1. Conducting conductor (TPA): annealed copper wire
2. Insulation: solid, PE
3. Pair: two insulated conductors twisted together with agreed steps and with the following color identification:
- pair 1: white-blue / blue
- pair 2: white-orange / orange
- pair 3: white-green / green
- pair 4: white-brown / brown
4. Pair separator (cordell): PE or LSFRZH
5. Belt insulation: PET-E film, overlapping
6. Core screen : aluminum-polymer tape (metal inside)
7. Drain conductor: tinned copper wire with a diameter of 0.4 mm (under the screen)
8. Sheath: PVC, LSZH or LSFRZH
Cable requirement: DSTU IEC 61156-5, DSTU EN 50288-5-1, TU U 27.3-05758730-097: 2018
Cable requirement: DSTU ISO / IEC 11801, DSTU EN 50173-1
Fire safety:
- PVC: DSTU 4809: 2017 (Clause 5.1), DSTU EN 60332-1-2
- LSZH: DSTU 4809: 2017 (Clause 5.1, 5.3-5.5), DSTU EN 60332-1-2, DSTU EN 60754-1, DSTU EN 60754 -2, DSTU EN 61034-2
- LSFRZH: DSTU 4809: 2017 (Clauses 5.1-5.5), DSTU EN 60332-1-2, DSTU EN 60332-3, DSTU EN 60754-1, DSTU EN 60754-2, DSTU EN 61034-2
Temperature range:
- during installation: -10 ° C ... + 60 ° C
- during operation: -20 ° C ... + 60 ° C
Bending radius: ≥ 10 cable diameters
Tensile force: ≤ 85 N
| Parameter | Ed. ed. | Value |
| Working capacity, no more | nF / km | 56 |
| Electrical resistance tfzh to direct current: | Om / km | |
| - with a diameter of 0.54 mm, no more | 83 | |
| - with a diameter of TPG 0.57 mm, not more than | 88 | |
| Ohmic asymmetry lived in pairs, no more | % | 2 |
| Electrical insulation resistance, not less | GOm / km | 5 |
| Nominal signal propagation speed | % | 68 |
| Wave impedance module | Ohm | |
| - in the frequency range from 1 to 100 MHz | 100 +/- 15 | |
| - in the frequency range from 101 to 250 MHz | 100 +/- 22 | |
| DC test voltage between conductors, conductors and shield for 2 seconds | kV | 2.5 |
| Frequency, MHz | 1 | 4 | 10 | 16 | 20 | 31.25 | 62.5 | 100 | 250 |
| Own attenuation, dB / 100 m, no more | 2.1 | 3.8 | 6 | 7.6 | 8.5 | 10.7 | 15.5 | 19.9 | 33 |
| NEXT, dB, not less | 75.3 | 66.3 | 60.3 | 57.2 | 55.8 | 52.9 | 48.4 | 45.3 | 39.3 |
| PS NEXT, dB, not less | 72.3 | 63.3 | 57.3 | 54.2 | 52.8 | 49.9 | 45.4 | 42.3 | 36.3 |
| ELFEXT, dB, not less | 68 | 56 | 48 | 43.9 | 42 | 38.1 | 32.1 | 28 | 20 |
| PS ELFEXT, dB, not less | 65 | 53 | 45 | 40.9 | 39 | 35.1 | 29.1 | 25 | 17 |
| Return Loss, dB, not less | 20 | 2. 3 | 25 | 25 | 25 | 23.6 | 21.5 | 20.1 | 17.3 |
| Code | Name | Shell | Diameter of TPG, mm | Conductor diameter mm | Diameter / cable size, mm | Packaging | Estimated weight, kg / km |
| 49342 | KPVE-VP (250) 4 * 2 * 0.57 (F / UTP-cat.6) | PVC | 0.57 | 1.11 | 6.9 | plywood coil 305/500/1000 m | 49.5 |
| 7932024 | KPVong-HFE-VP (250) 4 * 2 * 0.57 (F / UTP-cat.6 LSOH) | LSZH | 0.57 | 1.11 | 6.9 | plywood coil 305/500/1000 m | 49.9 |
| 7932106 | KPVng-HFE-VP (250) 4 * 2 * 0.57 (F / UTP-cat.6 LSFROH) | LSZFRZH | 0.57 | 1.11 | 6.9 | plywood coil 305/500/1000 m | 55.7 |
| 7932020 | KPVE-VP (250) 4 * 2 * 0.54 (F / UTP-cat.6) | PVC | 0.54 | 1.03 | 6.7 | plywood coil 305/500/1000 m | 46.1 |
| 7932025 | KPVong-HFE-VP (250) 4 * 2 * 0.54 (F / UTP-cat.6 LSOH) | LSZH | 0.54 | 1.03 | 6.7 | plywood coil 305/500/1000 m | 46.5 |
| 7932109 | KPVng-HFE-VP (250) 4 * 2 * 0.54 (F / UTP-cat.6 LSFROH) | LSZFRZH | 0.54 | 1.03 | 6.7 | plywood coil 305/500/1000 m | 49.2 |