Application

PBX, V.11, X.21, ISDN, Ethernet (10Base-T), ATM-25/52/155 Mbit/s, 100VG-AnyLAN, Fast Ethernet (100BASE-TX), Token Ring 16/100 Mbit/s, Firewire 100 Mbit/s, PoE (IEEE 802.3af), PoE+ (IEEE 802.3at), PoE++ (IEEE 802.3bt), HDBaseT, 1000BASE-T, 2.5GBASE-T, 5GBASE-T, 10GBASE-T (до 55 метров)

Typical design

 
Cable structure

1. Conducting conductor (TPA): annealed copper wire
2. Insulation: solid, PE
3. Pair: two insulated conductors twisted together with agreed steps and with the following color identification:
- pair 1: white-blue / blue
- pair 2: white-orange / orange
- pair 3: white-green / green
- pair 4: white-brown / brown
4. Pair separator (cordel): PE or LSFRZH
5. Shell: PVC, LSZH or LSFRZH

Standards / TU

Cable requirement: DSTU IEC 61156-5, DSTU EN 50288-6-1, TU U 27.3-05758730-097: 2018
Cable requirement: DSTU ISO / IEC 11801, DSTU EN 50173-1
Fire safety:
- PVC: DSTU 4809: 2017 (Clause 5.1), DSTU EN 60332-1-2
- LSZH: DSTU 4809: 2017 (Clause 5.1, 5.3-5.5), DSTU EN 60332-1-2, DSTU EN 60754-1, DSTU EN 60754 -2, DSTU EN 61034-2
- LSFRZH: DSTU 4809: 2017 (Clauses 5.1-5.5), DSTU EN 60332-1-2, DSTU EN 60332-3, DSTU EN 60754-1, DSTU EN 60754-2, DSTU EN 61034-2

Main technical and operational characteristics

Temperature range:
- during installation: -10 ° C ... + 60 ° C
- during operation: -20 ° C ... + 60 ° C
Bending radius: ≥ 10 cable diameters
Tensile force: ≤ 85 N

Electrical characteristics at 20 0 С

 

Parameter Ed. ed. Value
Working capacity, no more nF / km 56
Electrical resistance tfzh to direct current: Om / km  
- with a diameter of 0.55 mm, no more   87
- with a diameter of 0.54 mm, no more   82
- with a diameter of TPG 0.57 mm, not more than   75
Ohmic asymmetry lived in pairs, no more % 2
Electrical insulation resistance, not less GOm / km 5
Nominal signal propagation speed % 68
Wave impedance module Ohm  
- in the frequency range from 1 to 100 MHz   100 +/- 15
- in the frequency range from 101 to 250 MHz   100 +/- 22
DC test voltage between conductors, conductors and shield for 2 seconds kV 2.5

 

Signal transmission characteristics at 20 0 C

 

Frequency, MHz 1 4 10 16 20 31.25 62.5 100 250
Own attenuation, dB / 100 m, no more 2.1 3.8 6 7.6 8.5 10.7 15.5 19.9 33
NEXT, dB, not less 75.3 66.3 60.3 57.2 55.8 52.9 48.4 45.3 39.3
PS NEXT, dB, not less 72.3 63.3 57.3 54.2 52.8 49.9 45.4 42.3 36.3
ELFEXT, dB, not less 68 56 48 43.9 42 38.1 32.1 28 20
PS ELFEXT, dB, not less 65 53 45 40.9 39 35.1 29.1 25 17
Return Loss, dB, not less 20 2. 3 25 25 25 23.6 21.5 20.1 17.3

 

Order Information

 

7931167 KPV-VP (250) 4 * 2 * 0.57 (U / UTP-cat.6) PVC 0.57 1.09 6.0 box 305 m 40.1
49 218 KPVong-HF-VP (250) 4 * 2 * 0.57 (U / UTP-cat.6 LSOH) LSZH 0.57 1.09 6.0 box 305 m 39.5
49210 CPVng-HF-VP (250) 4 * 2 * 0.57 (U / UTP-cat.6 LSFROH) LSZFRZH 0.57 1.09 6.0 box 305 m 40.5
7931193 KPV-VP (250) 4 * 2 * 0.54 (U / UTP-cat.6) PVC 0.54 0.94 5.6 box 305 m 35.7
49 213 KPVong-HF-VP (250) 4 * 2 * 0.54 (U / UTP-cat.6 LSOH) LSZH 0.54 0.94 5.6 box 305 m 35.0
7931189 CPVng-HF-VP (250) 4 * 2 * 0.54 (U / UTP-cat.6 LSFROH) LSZFRZH 0.54 0.94 5.6 box 305 m 37.6
7931099 KPV-VP (250) 4 * 2 * 0.52 (U / UTP-cat.6) PVC 0.525 0.91 5.4 box 305 m 35.8
7931154 KPVong-HF-VP (250) 4 * 2 * 0.52 (U / UTP-cat.6 LSOH) LSZH 0.525 0.91 5.4 box 305 m 33.7
7931199 CPVng-HF-VP (250) 4 * 2 * 0.52 (U / UTP-cat.6 LSFROH) LSZFRZH 0.525 0.91 5.4 box 305 m 34.7