Print
Back to: Communication cables, telephone and station
Communication cables, telephone and station

Telephone cable TPPepZ

s3__1581432166_574
Rating: Not Rated Yet
Product Code:
Ai intrebari sau ai nevoie de asistenta pentru finalizarea comenzii ?
Trimite mail la : adresa@e.mail
Disponibilitate: Stoc epuizat

Application

The cable is designed for operation in local primary communication networks and communication lines with a nominal voltage of remote power supply up to 145 V AC at a frequency of 50 Hz or voltage up to 200 V DC.
Laying in telephone sewers, in collectors, mines, along the walls of buildings and suspension on overhead communication lines, in conditions of high humidity.

Typical design

 
Cable structure

1. Conducting vein - a copper soft wire of Ø 0,32; 0.40; 0.50; 0.64; 0.70 or 0.90 mm.

2. Core insulation - polyethylene (PE), continuous. Insulated cores, sharply different in color, are twisted in a pair.

3. Elementary bundle - is formed of 5 or 10 pairs. All pairs in an elementary beam have an individual color. The bundle fastening winding is a synthetic thread or ribbon of individual color for each bundle.

4. The core of the cable consists of elementary 5 or 10 pair bundles (in cables with a number of pairs up to 100 inclusive) or of main bundles (in cables with a number of pairs more than 100). The fastening winding of the bundles and core is a synthetic thread or ribbon of individual color for each bundle.

5. The free space between the cores in the core is filled with a hydrophobic aggregate.

6. Belt insulation - a synthetic tape (PET-E, PE, polyamide or paper-polyethylene), applied longitudinally or helically. A layer of hydrophobic aggregate or water blocking tape is laid over the waist insulation.

7. Screen - aluminum-polyethylene tape, applied longitudinally or helically. A tinned copper wire Ø 0.4 or 0.5 mm is longitudinally laid under the screen.

8. Shell - light stabilized PE.

Standards / TU

TU U 05758730.014-2000
IEC 60708-1
IEC 60189-1
GOST R 51311-99
BS 3573

Execution options

It is possible to manufacture on special order cable TPPepzv brand with a working capacity value according to IEC standards

Main technical and operational characteristics

 

Operating temperature range: -50 ° C to +50 ° C            
Temperature range of laying and installation: -10 ° C to +50 ° C            
Bending radius of at least 10 cable diameters            
Minimum service life 25 years            
Diameter of conductive conductors, mm, nom. 0.32 0.40 0.50 0.64 0.70 0.90
Electrical resistance of a conducting conductor to a direct current, Ohm / km, nom. 216 139 90 55 45 27.4
Operating capacitance at frequencies from 0.8 to 1.0 kHz, nF / km, nom.            
- for cables of execution "Z" fifty fifty fifty fifty fifty fifty
- for cables of execution "Sv" (average value, no more) 53 55 55 57 57 57
Electrical insulation resistance, MΩ • km, not less 5000 5000 5000 5000 5000 5000

 

Estimated outer diameter of the cable, mm (informative)

 

Number of pairs 0.32 0.40 0.50 0.64 0.70 0.90
5 6.4 7.1 8.0 9.0 9.7 12.3
10 7.6 8.6 10.3 11.3 12.7 15.9
20 9.5 11.3 13,4 15.4 16.8 21.5
thirty 11.1 13.0 15.3 17.8 19.9 25,4
fifty 14.0 16,4 19.5 22.7 25,2 33.0
100 18.0 21.8 26.0 30.5 33.6 44.1
200 24.4 29.3 35.6 42.1 46,4  
300 28.8 35.7 42.3 50,2 55,4  
400 32,4 40.3 47.9 57.0    
500 36.7 44.3 52.8 63.0    
600 39.6 48.0 57.2      
700 42.3 51.3 61.3      
800 44.8 54,4        
900 47.1 57.4        
1000 49.3 60.1        
1200 53,4 65.3        

 

Estimated weight of the cable, kg / km (informative)

 

Number of pairs 0.32 0.40 0.50 0.64 0.70 0.90
5 43 54 69 93 103 166
10 61 82 121 153 194 289
20 100 151 210 295 355 546
thirty 146 202 285 408 503 778
fifty 232 328 476 687 833 1319
100 402 588 873 1282 1538 2444
200 757 1109 1663 2467 2967  
300 1070 1630 2390 3577 4314  
400 1381 2114 3102 4668    
500 1742 2586 3811 5756    
600 2047 3054 4510      
700 2224 3525 5210      
800 2507 3985        
900 2954 4446        
1000 3253 4905        
1200 3846 5811