The cable is designed for operation in local primary communication networks and communication lines with a nominal voltage of remote power supply up to 145 V AC at a frequency of 50 Hz or voltage up to 200 V DC.
Laying in telephone sewers, in collectors, mines, along the walls of buildings and suspension on overhead communication lines, in conditions of high humidity.
1. Conducting vein - a copper soft wire of Ø 0,32; 0.40; 0.50; 0.64; 0.70 or 0.90 mm.
2. Core insulation - polyethylene (PE), continuous. Insulated cores, sharply different in color, are twisted in a pair.
3. Elementary bundle - is formed of 5 or 10 pairs. All pairs in an elementary beam have an individual color. The bundle fastening winding is a synthetic thread or ribbon of individual color for each bundle.
4. The core of the cable consists of elementary 5 or 10 pair bundles (in cables with a number of pairs up to 100 inclusive) or of main bundles (in cables with a number of pairs more than 100). The fastening winding of the bundles and core is a synthetic thread or ribbon of individual color for each bundle.
5. The free space between the cores in the core is filled with a hydrophobic aggregate.
6. Belt insulation - a synthetic tape (PET-E, PE, polyamide or paper-polyethylene), applied longitudinally or helically. A layer of hydrophobic aggregate or water blocking tape is laid over the waist insulation.
7. Screen - aluminum-polyethylene tape, applied longitudinally or helically. A tinned copper wire Ø 0.4 or 0.5 mm is longitudinally laid under the screen.
8. Shell - light stabilized PE.
TU U 05758730.014-2000
IEC 60708-1
IEC 60189-1
GOST R 51311-99
BS 3573
It is possible to manufacture on special order cable TPPepzv brand with a working capacity value according to IEC standards
| Operating temperature range: -50 ° C to +50 ° C | ||||||
| Temperature range of laying and installation: -10 ° C to +50 ° C | ||||||
| Bending radius of at least 10 cable diameters | ||||||
| Minimum service life 25 years | ||||||
| Diameter of conductive conductors, mm, nom. | 0.32 | 0.40 | 0.50 | 0.64 | 0.70 | 0.90 |
| Electrical resistance of a conducting conductor to a direct current, Ohm / km, nom. | 216 | 139 | 90 | 55 | 45 | 27.4 |
| Operating capacitance at frequencies from 0.8 to 1.0 kHz, nF / km, nom. | ||||||
| - for cables of execution "Z" | fifty | fifty | fifty | fifty | fifty | fifty |
| - for cables of execution "Sv" (average value, no more) | 53 | 55 | 55 | 57 | 57 | 57 |
| Electrical insulation resistance, MΩ • km, not less | 5000 | 5000 | 5000 | 5000 | 5000 | 5000 |
| Number of pairs | 0.32 | 0.40 | 0.50 | 0.64 | 0.70 | 0.90 |
| 5 | 6.4 | 7.1 | 8.0 | 9.0 | 9.7 | 12.3 |
| 10 | 7.6 | 8.6 | 10.3 | 11.3 | 12.7 | 15.9 |
| 20 | 9.5 | 11.3 | 13,4 | 15.4 | 16.8 | 21.5 |
| thirty | 11.1 | 13.0 | 15.3 | 17.8 | 19.9 | 25,4 |
| fifty | 14.0 | 16,4 | 19.5 | 22.7 | 25,2 | 33.0 |
| 100 | 18.0 | 21.8 | 26.0 | 30.5 | 33.6 | 44.1 |
| 200 | 24.4 | 29.3 | 35.6 | 42.1 | 46,4 | |
| 300 | 28.8 | 35.7 | 42.3 | 50,2 | 55,4 | |
| 400 | 32,4 | 40.3 | 47.9 | 57.0 | ||
| 500 | 36.7 | 44.3 | 52.8 | 63.0 | ||
| 600 | 39.6 | 48.0 | 57.2 | |||
| 700 | 42.3 | 51.3 | 61.3 | |||
| 800 | 44.8 | 54,4 | ||||
| 900 | 47.1 | 57.4 | ||||
| 1000 | 49.3 | 60.1 | ||||
| 1200 | 53,4 | 65.3 |
| Number of pairs | 0.32 | 0.40 | 0.50 | 0.64 | 0.70 | 0.90 |
| 5 | 43 | 54 | 69 | 93 | 103 | 166 |
| 10 | 61 | 82 | 121 | 153 | 194 | 289 |
| 20 | 100 | 151 | 210 | 295 | 355 | 546 |
| thirty | 146 | 202 | 285 | 408 | 503 | 778 |
| fifty | 232 | 328 | 476 | 687 | 833 | 1319 |
| 100 | 402 | 588 | 873 | 1282 | 1538 | 2444 |
| 200 | 757 | 1109 | 1663 | 2467 | 2967 | |
| 300 | 1070 | 1630 | 2390 | 3577 | 4314 | |
| 400 | 1381 | 2114 | 3102 | 4668 | ||
| 500 | 1742 | 2586 | 3811 | 5756 | ||
| 600 | 2047 | 3054 | 4510 | |||
| 700 | 2224 | 3525 | 5210 | |||
| 800 | 2507 | 3985 | ||||
| 900 | 2954 | 4446 | ||||
| 1000 | 3253 | 4905 | ||||
| 1200 | 3846 | 5811 |