The cable is designed for operation in local primary communication networks and communication lines with a nominal voltage of remote power supply up to 145 V AC at a frequency of 50 Hz or voltage up to 200 V DC.
Laying in telephone sewers, in collectors, mines, along the walls of buildings and suspension on overhead communication lines, in conditions of high humidity.
1. Conducting vein - a copper soft wire of Ø 0,40; 0.50; 0.60; 0.80 or 0.90 mm.
2. Core insulation - polyethylene (PE), continuous.
Insulated cores, sharply different in color, are twisted into a four. In each four, two veins located diagonally form a working pair.
3. Elementary beam - formed of 5 fours. All fours in an elementary bunch have an individual color.
4. The core of the cable consists of elementary 5 four-way bundles (in cables with the number of fours up to 50 inclusive) or of the main 25 or 50 four-way bundles (in cables with the number of fours over 50). The fastening winding of the bundles and core is a synthetic thread or ribbon of individual color for each bundle.
5. The free space between the cores in the core is filled with a hydrophobic aggregate.
6. Belt insulation - a synthetic tape (PET-E, PE, polyamide or paper-polyethylene), applied longitudinally or helically. A layer of hydrophobic aggregate or water blocking tape is laid over the waist insulation.
7. Screen - aluminum-polyethylene tape, applied longitudinally or helically. A tinned copper wire Ø 0.4 mm is longitudinally laid under the screen.
8. Shell - light stabilized PE.
TU U 05758730-040-2006
IEC 60708-1
IEC 60189-1
| Operating temperature range: -50 ° C to +50 ° C | |||||
| Temperature range of laying and installation: -10 ° C to +50 ° C | |||||
| Bending radius of at least 10 cable diameters | |||||
| Minimum service life 25 years | |||||
| Diameter of conductive conductors, mm, nom. | 0.40 | 0.50 | 0.60 | 0.80 | 0.90 |
| Electrical resistance of a conductive vein to a direct current, Ohm / km, no more | 148 | 96 | 65 | 36.6 | 28,4 |
| Working capacity at a frequency from 0.8 to 1.0 kHz, nF / km, not more than | 55 | 55 | 55 | 55 | 55 |
| Electrical insulation resistance, MΩ • km, not less | 5000 | 5000 | 5000 | 5000 | 5000 |
| Capacitive coupling coefficient k1, calculated for 300 m of length, pF, not more than | 600 | 600 | 600 | 600 | 600 |
| Capacitive coupling coefficients k9-k12, recalculated for 300 m of length, pF, no more | 300 | 300 | 300 | 300 | 300 |
| The number of fours | 0.40 mm | 0.50 mm | 0.60 mm | 0.80 mm | 0.90 mm |
| 5 | 7.9 | 9.0 | |||
| 10 | 9.5 | 11.1 | |||
| fifteen | 11,4 | 13.6 | |||
| 20 | 12.6 | 15,2 | |||
| 25 | 14.0 | 16.6 | |||
| fifty | 18.8 | 22.5 | |||
| 75 | 22.1 | ||||
| 100 | 25.3 | 30.6 | |||
| 150 | 30.1 | 37.6 | |||
| 200 | 35.1 | 42.6 | |||
| 250 | 38.6 | ||||
| 300 | 41.8 |