Print
Back to: Communication cables, telephone and station
Communication cables, telephone and station

Telephone cable TPPep-NDG

s13__1581494402_595
Rating: Not Rated Yet
Product Code:
Ai intrebari sau ai nevoie de asistenta pentru finalizarea comenzii ?
Trimite mail la : adresa@e.mail
Disponibilitate: Stoc epuizat

Application

The cable is designed for operation in local primary communication networks and communication lines with a nominal voltage of remote power supply up to 145 V AC at a frequency of 50 Hz or voltage up to 200 V DC.
Laying in telephone sewers, in collectors, mines, along the walls of buildings, in conditions of increased fire safety requirements, as well as for internal laying on the walls of buildings and in rooms.

Typical design

 
Cable structure

1. Conducting vein - a copper soft wire of Ø 0,40 or 0,50 mm.

2. Core insulation - polyethylene (PE), continuous.
Insulated cores, sharply different in color, are twisted in a pair.

3. Elementary bundle - is formed of 5 or 10 pairs. All pairs in an elementary beam have an individual color.

4. The core of the cable consists of elementary 5 or 10 pair bundles (in cables with a number of pairs up to 100 inclusive) or of main bundles (in cables with a number of pairs more than 100). The fastening winding of the bundles and core is a synthetic thread or ribbon of individual color for each bundle.

5. Belt insulation - a synthetic tape (PP, PET-E or PE), applied longitudinally or helically.

6. Screen - aluminum-polyethylene tape, applied longitudinally or helically. A tinned copper wire Ø 0.4 or 0.5 mm is longitudinally laid under the screen.

7. Shell - a compound with reduced flammability and corrosiveness of the smoke and gas product, halogen-free.

Standards / TU

TU U 05758730.070-2010
IEC 60708-1
IEC 60189-1
GOST R 51311-99
BS 3573

Execution options

 

Main technical and operational characteristics

 

Operating temperature range: -50 ° C to +60 ° C    
Temperature range of laying and installation: -15 ° C to +60 ° C    
Bending radius of at least 10 cable diameters    
Minimum service life - 20 years    
Diameter of conductive conductors, mm, nom. 0.40 0.50
Electrical resistance of a conducting conductor to a direct current, Ohm / km, nom. 139 90
Operating capacitance at frequencies from 0.8 to 1.0 kHz, nF / km, nom. 45 ± 5 45 ± 5
Electrical insulation resistance, MΩ • km, not less 6500 6500
Fire hazard class P1.8.2.2.2    

 

Estimated outer diameter of the cable, mm (informative)

 

Number of pairs 0.40 mm 0.50 mm
5 7.2 8.0
10 8.5 9.7
20 10.6 12.9
thirty 12.1 14.7
fifty 15.1 17.8
100 20.6 24.4
200 28.3 33.6
300 33.1 40.7

 

Estimated weight of the cable, kg / km (informative)

 

Number of pairs 0.40 mm 0.50 mm
5 61 76
10 86 111
20 135 185
thirty 180 260
fifty 285 390
100 528 734
200 1000 1430
300 1387 2096