Print
Back to: Category 7A LAN Cables
Category 7A LAN Cables

S⁄FTP 4Pr Outdoor

Temple_copy__1581510633_142
Rating: Not Rated Yet
Product Code:
Ai intrebari sau ai nevoie de asistenta pentru finalizarea comenzii ?
Trimite mail la : adresa@e.mail
Disponibilitate: Stoc epuizat

Application

PBX, V.11, X.21, ISDN, Ethernet (10Base-T), ATM-25/52/155 Mbit/s, 100VG-AnyLAN, Fast Ethernet (100BASE-TX), Token Ring 16/100 Mbit/s, Firewire 100 Mbit/s, PoE (IEEE 802.3af), PoE+ (IEEE 802.3at), PoE++ (IEEE 802.3bt), HDBaseT, 1000BASE-T, 2.5GBASE-T, 5GBASE-T, 10GBASE-T

Typical design

 
Cable structure

1. Conducting conductor (TPA): annealed copper wire
2. Insulation: film-porous, PE
3. Pair: two insulated conductors twisted together with the agreed steps and with the following color identification:
- pair 1: white / blue
- pair 2: white / orange
- pair 3: white / green
- pair 4: white / brown
Pair screen: aluminum-polymer tape (metal to the outside)
4. Belt insulation: PET-E film, no overlap (with clearance)
5. Core screen: copper braid tinned wire
6. Sheath: light-stabilized black PE

Standards / TU

Cable requirement: DSTU IEC 61156-5, DSTU EN 50288-9-1, TU U 27.3-05758730-097: 2018
Cable requirement: DSTU ISO / IEC 11801, DSTU EN 50173-1

Main technical and operational characteristics

Temperature range:
- during installation: -10 ° C ... + 60 ° C
- during operation: -50 ° C ... + 60 ° C
Bending radius: ≥ 10 cable diameters
Tensile force: ≤ 85 N

Electrical characteristics at 20 0 С

Parameter Ed. ed. Value
Working capacity, no more nF / km 56
Electrical resistance tfzh to direct current, no more Om / km 71
Ohmic asymmetry lived in pairs, no more % 2
Electrical insulation resistance, not less GOm / km 5
Nominal signal propagation speed % 80
Wave impedance module Ohm  
- in the frequency range from 1 to 100 MHz   100 +/- 15
- in the frequency range from 101 to 250 MHz   100 +/- 22
- in the frequency range from 251 to 1000 MHz   100 +/- 25
DC test voltage between conductors, conductors and shield for 2 seconds kV 2.5

Signal transmission characteristics at 20 0 C

Frequency, MHz 1 4 10 16 20 31.25 62.5 100 250 500 600 1000
Own attenuation, dB / 100 m, no more 2 3.7 5.8 7.3 8.2 10.3 14.8 18.5 29.7 42.8 47.1 61.9
NEXT, dB, not less 78 78 78 78 78 78 78 75.4 69.4 64.9 63.7 60.4
PS NEXT, dB, not less 75 75 75 75 75 75 75 72.4 66.4 61.9 60.7 57.4
ELFEXT, dB, not less 78 78 75.3 71.2 69.3 65.4 59.4 55.3 47.3 41.3 39.7 35.3
PS ELFEXT, dB, not less 75 75 72.3 68.2 66.3 62.4 56.4 52.3 44.3 38.3 36.7 32.3
Return Loss, dB, not less 20 2. 3 25 25 25 23.6 21.5 20.1 17.3 17.3 17.3 15.1

Order Information

Code Name Shell Diameter of TPG, mm Conductor diameter mm Braid density Diameter / cable size, mm Packaging Estimated weight, kg / km
7935107 KPPPO-VPE (1000) 4 * 2 * 0.58 (S / FTP-cat.7A) ON 0,585 1.42 54% 7.5 plywood coil 305/500/1000 m 56,4