The cable is designed for inter-office and subscriber communication lines with multiplexing transmission systems with time division of channels and pulse-code modulation with a transmission speed of up to 2048 kBit / s with a remote supply voltage of up to 500 V DC.
Laying in soils that are not subject to displacement, not characterized by increased corrosion hazard in relation to steel armor, in conditions of high humidity.
1. Conducting vein - a copper wire of Ø 0,9 or 1,2 mm.
2. Core insulation - polyethylene (PE), continuous.
Four isolated cores are twisted into a four. In the four, two veins located diagonally form a working pair. The insulation of the cores of one pair is a natural color, the other pair is blue or another, different from natural.
3. Cordel (central element) - PE.
4. The free space between the cores in the core is filled with a hydrophobic aggregate.
5. Belt insulation - PE extruded.
6. Screen - aluminum foil applied longitudinally. A tinned copper wire Ø 0.4 mm is longitudinally laid under the screen.
7. Armor - steel laminated corrugated tape applied longitudinally with overlapping.
8. Shell - light stabilized PE.
TU U 05758730.010-98
| Operating temperature range: -50 ° C to +50 ° C | ||
| Temperature range for installation and installation: -10 ° C to +50 ° C | ||
| Bending radius during installation - at least 15 cable diameters | ||
| Minimum cable life of 20 years | ||
| Diameter of conductive conductors, mm, nom. | 0.9 | 1.2 |
| Electrical resistance of conductive veins to a direct current, Ohm / km, no more | 28.4 | 15.8 |
| Ohmic asymmetry, calculated for a length of 750 m, Ohm, not more than | 1.0 | 1.0 |
| Insulation resistance of conductors to direct current, MΩ • km, not less | 15000 | 15000 |
| Operating capacitance at a frequency of 0.8 to 1.0 kHz, nF / km, nom. | 35.0 ± 3 | 43.5 ± 3 |
| Electrical insulation resistance of the shell to direct current, MΩ • km, not less | 5.0 | 5.0 |
| Transient attenuation between cable circuits at the near end (see note), dB, not less | 59 | 59 |
| Security between cable chains at the far end (see note), dB, not less | 45 | 45 |
| Note: recalculation to a length of 750 m, with a digital influence signal | ||
| in the form of a pseudo-random sequence at a transmission rate of 2048 kBit / s |
| Cable brand | 0.9 mm | 1.2 mm |
| 1x4x CSP ... | 13.2 | 13.2 |
| Cable brand | 0.9 mm | 1.2 mm |
| 1x4x CSP ... | 201 | 218 |