The wire is designed for transmission and distribution of electricity in power and lighting networks to a rated voltage of up to 380 V AC with a frequency of 50 Hz. Outdoor gasket for entering residential buildings and farm buildings of I and II glazed areas.
1. Conducting vein - aluminum single-wire section of 16 mm2;
2. Insulation of the inner core - PVC compound;
3. Concentric external core - aluminum wires;
4. Shell - light stabilized cross-linked polyethylene.
1. AVKAPs with multi-wire conductive core;
2. AVKAPst - a wire with a bearing element (cable).
TU U 31.3-05758730-048: 2007
| Operating temperature | from -50 ° С to + 50 ° С |
| Minimum bending radius (during installation and wire installed on supports) | 10 wire diameters |
| Wire size | Outer diameter of wire (reference), mm | Mass of cable, kg / km (informative) |
| AVCAPs 16/16 | 11.5 | 158 |
| AVKAPst 16/16 | 16.8 x 11.7 | 187 |
APPENDIX B. Reference information on permissible current loads of self-supporting SIP wires