The cable is designed for operation in local primary communication networks and communication lines with a nominal voltage of remote power supply up to 145 V AC at a frequency of 50 Hz or voltage up to 200 V DC.
Laying on the inner walls of buildings and indoors.
1. Conducting vein - a copper soft wire of Ø 0,40; 0.50 or 0.64 mm.
2. Core insulation - polyethylene (PE), continuous.
Insulated cores, sharply different in color, are twisted in a pair.
3. Elementary bundle - is formed of 5 or 10 pairs. All pairs in an elementary beam have an individual color. The bundle fastening winding is a synthetic thread or ribbon of individual color for each bundle.
4. The core of the cable consists of elementary 5 or 10 pair bundles. The fastening winding of the bundles and core is a synthetic thread or ribbon of individual color for each bundle.
5. Belt insulation - synthetic tape (PVC, PET-E, PE or polyamide), applied longitudinally or helically.
6. Screen - aluminum or aluminum-polyethylene tape, applied longitudinally or helically. A tinned copper wire Ø 0.4 or 0.5 mm is longitudinally laid under the screen.
7. Shell - polyvinyl chloride plastic compound (PVC).
TU U 05758730.014-2000
IEC 60708-1
IEC 60189-1
GOST R 51311-99
BS 3573
For laying in bundles of cables on cable ducts and in gutters, it is possible to manufacture a TPVng cable with a low-combustibility PVC sheath; upon presentation of requirements for reduced smoke and gas emission - TPVng-LS with a PVC sheath with reduced smoke and gas emission.
| Operating temperature range: -40 ° C to +60 ° C | |||
| Temperature range for installation and installation: -10 ° C to +60 ° C | |||
| Bending radius of at least 10 cable diameters. | |||
| Minimum service life - 20 years | |||
| Diameter of conductive conductors, mm, nom. | 0.40 | 0.50 | 0.64 |
| Electrical resistance of a conducting conductor to a direct current, Ohm / km, nom. | 139 | 90 | 55 |
| Operating capacitance at frequencies from 0.8 to 1.0 kHz, nF / km, nom. | 45 ± 5 | 45 ± 5 | 45 ± 5 |
| Electrical insulation resistance, not less, MΩ • km | 6500 | 6500 | 6500 |
| Number of pairs | 0.40 mm | 0.50 mm | 0.64 mm |
| 5 | 7.2 | 8.0 | 9.1 |
| 10 | 8.5 | 9.7 | 11.1 |
| 20 | 10.6 | 12.3 | 15.0 |
| thirty | 12.0 | 14.7 | 17,2 |
| fifty | 15.1 | 17.8 | 22.0 |
| 100 | 20.6 | 24.4 | 29.9 |
| Number of pairs | 0.40 mm | 0.50 mm | 0.64 mm |
| 5 | 62 | 78 | 102 |
| 10 | 89 | 117 | 158 |
| 20 | 139 | 189 | 286 |
| thirty | 182 | 272 | 385 |
| fifty | 292 | 407 | 637 |
| 100 | 542 | 768 | 1188 |