Print
Back to: Communication cables, telephone and station
Communication cables, telephone and station

Cable telephone TPV

s14__1581494883_435
Rating: Not Rated Yet
Product Code:
Ai intrebari sau ai nevoie de asistenta pentru finalizarea comenzii ?
Trimite mail la : adresa@e.mail
Disponibilitate: Stoc epuizat

Application

The cable is designed for operation in local primary communication networks and communication lines with a nominal voltage of remote power supply up to 145 V AC at a frequency of 50 Hz or voltage up to 200 V DC.
Laying on the inner walls of buildings and indoors.

Typical design

 
Cable structure

1. Conducting vein - a copper soft wire of Ø 0,40; 0.50 or 0.64 mm.

2. Core insulation - polyethylene (PE), continuous.
Insulated cores, sharply different in color, are twisted in a pair.

3. Elementary bundle - is formed of 5 or 10 pairs. All pairs in an elementary beam have an individual color. The bundle fastening winding is a synthetic thread or ribbon of individual color for each bundle.

4. The core of the cable consists of elementary 5 or 10 pair bundles. The fastening winding of the bundles and core is a synthetic thread or ribbon of individual color for each bundle.

5. Belt insulation - synthetic tape (PVC, PET-E, PE or polyamide), applied longitudinally or helically.

6. Screen - aluminum or aluminum-polyethylene tape, applied longitudinally or helically. A tinned copper wire Ø 0.4 or 0.5 mm is longitudinally laid under the screen.

7. Shell - polyvinyl chloride plastic compound (PVC).

Standards / TU

TU U 05758730.014-2000
IEC 60708-1
IEC 60189-1
GOST R 51311-99
BS 3573

Execution options

For laying in bundles of cables on cable ducts and in gutters, it is possible to manufacture a TPVng cable with a low-combustibility PVC sheath; upon presentation of requirements for reduced smoke and gas emission - TPVng-LS with a PVC sheath with reduced smoke and gas emission.

Main technical and operational characteristics

 

Operating temperature range: -40 ° C to +60 ° C      
Temperature range for installation and installation: -10 ° C to +60 ° C      
Bending radius of at least 10 cable diameters.      
Minimum service life - 20 years      
Diameter of conductive conductors, mm, nom. 0.40 0.50 0.64
Electrical resistance of a conducting conductor to a direct current, Ohm / km, nom. 139 90 55
Operating capacitance at frequencies from 0.8 to 1.0 kHz, nF / km, nom. 45 ± 5 45 ± 5 45 ± 5
Electrical insulation resistance, not less, MΩ • km 6500 6500 6500

 

Estimated outer diameter of the cable, mm (informative)

 

Number of pairs 0.40 mm 0.50 mm 0.64 mm
5 7.2 8.0 9.1
10 8.5 9.7 11.1
20 10.6 12.3 15.0
thirty 12.0 14.7 17,2
fifty 15.1 17.8 22.0
100 20.6 24.4 29.9

 

Estimated weight of the cable, kg / km (informative)

 

Number of pairs 0.40 mm 0.50 mm 0.64 mm
5 62 78 102
10 89 117 158
20 139 189 286
thirty 182 272 385
fifty 292 407 637
100 542 768 1188