Print
Back to: For underfloor heating (underfloor heating)
For underfloor heating (underfloor heating)

15 W heating cable on grid

Temple_Recovered_copy__1581503136_85
Rating: Not Rated Yet
Product Code:
Ai intrebari sau ai nevoie de asistenta pentru finalizarea comenzii ?
Trimite mail la : adresa@e.mail
Disponibilitate: Stoc epuizat

It is delivered in the form of ready-to-use products (sections) with a length of 6 to 128 meters, power from 0.09 to 1.93 kW (220 V)

 

Application

For heating rooms with low mechanical cable loads (class M1).
Operating temperature for cable operation, no more than 65 ° С. Power density max. 15 W / m.

Heating cable design

 
Product Description

A heating cable in which there are two conductive conductors made of copper (copper alloys, steel, nichrome), with insulation made of PVC compound with increased heat resistance, with protective elements - a screen made of aluminum foil, 2 aluminum ground wires and a sheath made of PVC compound.
To connect to the network has an attached power cable with a cross section of 3 * 0.75 square meters. mm The tightness class of the connection is IPX7.

Installation and operating conditions

Temperature range: -
during installation and laying: not lower - 5 ° С;
- during operation (fixed installation): from - 40 ° С to + 50 ° С;
bending radius: at least 6 cable thicknesses;
- tensile force: not more than 120 N;
- resistance to deformation by force, for cables of class M1: no more than 600 N.

Standards / TU

TU U 31.3-05758730-029: 2005;
TU U 31.3-05758730-084: 2012 MÉK
800

Electrical specifications

 

Article Length of cable Resistance, Ohm Power, W Price, UAH
1 0919001 6 529 92 590
2 0919002 9 376 129 690
3 0919003 13 261 186 790
4 0919004 18.5 178 273 950
5 0919005 2. 3 140 345 1050
6 0919006 29 109 444 1200
7 0919007 34 97.1 498 1250
8 0919008 38 84.7 571 1330
9 0919009 51 64.4 752 1650
10 0919010 59 54.6 886 1830
11 0919011 71 45.3 1068 2100
12 0919012 81 39.7 1219 2300
13 0919013 102 31.6 1531 2750
14 0919014 115 28.1 1725 2990
15 0919015 128 25.1 1929 3270

 

 



The deviation from electrical resistance does not exceed minus 5% and plus 10%.

The electrical resistance of the screen to direct current, calculated per 1 km of length and a temperature of 20 ° C - not more than 34.5 Ohms.

The electrical insulation resistance of the product, measured over 60 seconds with a voltage of 1000 Volts, at a temperature of 20 ° C - not less than 1 MOhm.

Marking

2х (specific electrical resistance of a core Ohm / m) HEATING CABLE ODESKABEL MAX 65 ° C
More: http://grayhot.com.ua

Mass and overall characteristics

Estimated cable size (reference), mm: 4.5 * 5.5.
Estimated mass of the cable (informative), kg / km: 28.4.