Print
Back to: Fire resistant cable
Fire resistant cable

Control cable fireproof halogen-free KMPvVEng-FRHF (FE180 / E30)

Temple_copy__1581424129_299
Rating: Not Rated Yet
Product Code:
Ai intrebari sau ai nevoie de asistenta pentru finalizarea comenzii ?
Trimite mail la : adresa@e.mail
Disponibilitate: Stoc epuizat

Application

The cable is intended for installation in alarm systems, signaling, sound warning and other similar systems, as well as for data processing systems and for transmitting analog or digital data in industrial electronics and control in facilities with increased requirements for fire protection, in particular, in fire alarm systems and automatic fire systems. Halogen-free cables are used where, in the event of a fire, increased safety for people and expensive electronic equipment is required. Supported cable functions - data transmission, supply voltage to equipment that must operate in a fire and during a fire extinguishing (for example, emergency lighting). The cables are fire resistant and their smoke emission is low, the emitted fumes are non-toxic and non-corrosive.

Typical design

 
Cable structure

1. Conducting vein: copper single-wire or multi-wire (1 or 2 class, \ according to DSTU EN60228);
2. Insulation - double layer:
- mica tape;
- halogen free compound.
(Insulated conductors are twisted in pairs)
3. Belt insulation: polymer tape;
4. Screen (general, electrostatic) - aluminum-polymer foil and tinned drain wire;
5. Shell: halogen-free compound of red color (other color on request).

Execution options

 

Compliance with the requirements

TU U 31.3-00217099-021: 2005;
DSTU EN 60228;
DSTU IEC 60502.

Main technical and operational characteristics

Operating temperature from -50 ° С to + 50 ° С
Minimum cable routing temperature without preheating -15 ° C
Permissible core heating temperature + 90 ° C
Minimum bending radius when laying: 7.5 cable diameters
Minimum service life 30 years

Nomenclature and mass-dimensional characteristics

Cable size Estimated outer diameter of the cable, mm (informative) Mass of cable, kg / km (informative)
KMPvVEng-FRHF (JE-H (St) H BD FE 180 / E30) 1 * 2 * 0.5 8.2 84
KMPvVEng-FRHF (JE-H (St) H BD FE 180 / E30) 1 * 2 * 1.0 10.3 124
KMPvVEng-FRHF (JE-H (St) H BD FE 180 / E30) 1 * 2 * 1.5 11,2 148
KMPvVEng-FRHF (JE-H (St) H BD FE 180 / E30) 2 * 2 * 0.5 9.1 111
KMPvVEng-FRHF (JE-H (St) H BD FE 180 / E30) 4 * 2 * 0.5 15,2 231
KMPvVEng-FRHF (JE-H (St) H BD FE 180 / E30) 8 * 2 * 0.5 26.1 477
KMPvVEng-FRHF (JE-H (St) H BD FE 180 / E30) 10 * 2 * 0.5 26.7 488
KMPvVEng-FRHF (JE-H (St) H BD FE 180 / E30) 2 * 2 * 0.9 eleven 150
KMPvVEng-FRHF (JE-H (St) H BD FE 180 / E30) 4 * 2 * 0.9 16.5 265
KMPvVEng-FRHF (JE-H (St) H BD FE 180 / E30) 5 * 2 * 0.9 18 310
KMPvVEng-FRHF (JE-H (St) H BD FE 180 / E30) 15 * 2 * 0.9 28.5 710
KMPvVEng-FRHF (JE-H (St) H BD FE 180 / E30) 24 * 2 * 0.9 35 1051